Loading... Please wait...The new Vivo life-support ventilator combines high quality technology, robustness and premium design to treat all patients in any environment in the best way.
Thanks to the user-friendly configuration of pressure and volume regulated modes, the treatment can be personalised to the patient’s needs. It also includes our patent-pending eSync technology and a full range of settings, including target volume which gives you unique flexibility.
Maximal flexibility of operation by the multiple types of circuit for both invasive and non-invasive ventilation.
As we care about comfort and flexibility the Vivo ventilator offers the possibility to pre-set up to three ventilation profiles. This allows the
patient to benefit from the optimal treatment at any time during the day.
Technical Specifications
Settings/Performance
Ventilation Modes • PSV • PSV(T)
• PCV • PCV(T)
• PCV(A) • PCV(A+T)
• VCV • VCV(A)
• CPAP
Device Modes • Home
• Clinical
Inspiratory Pressure 4 to 50 cmH2O
PEEP 2 cmH2O (leakage circuit),
0 cmH2O (circuit with active exhalation valve) to 30 cmH2O
Pressure - 2 cmH2O or Min Pressure -2 cmH2O
Breath Rate (PCV, VCV) 4 to 40 bpm
Inspiratory Time 0.3 to 5 s
Backup Inspiratory Time 0.3 to 5 s (PSV)
Rise Time 1 to 9 (PSV & PCV)
0.3 to 5 s (VCV)
Inspiratory Trigger 1 to 9 (PSV, PCV & VCV)
Off (PCV & VCV)
Expiratory Trigger 1 to 9 (PSV)
Minimum Inspiratory Time Off, 0.3 to 3 s
Maximum Inspiratory Time 0.3 to 3 s, Off
Backup Rate (PSV) 4 to 40 bpm
Target Volume 100 to 2500 ml
Maximum Pressure 50 cmH2O
Minimum Pressure 4 cmH2O to 50 cmH2O
Tidal Volume 100 to 2500 ml
Flow Pattern Square, decelerating
CPAP 4 to 20 cmH2O
Monitoring
Displayed data Ppeak, PEEP, MAP, Leakage, MV, Vt, FiO2, % in TV,
Total Rate, Spont Rate, % Spont, SpO2, Pulse Rate,
I:E, Inspiratory Time, Rise Time
Waveforms Pressure, Flow, Volume
Trends over 1, 6, 24 and 48h Ppeak, PEEP, Total Rate, Spont Rate, Vt, Leakage, SpO2
Breas Medical AB reserves the right to make changes to the contents of
this Product Specification without any prior notification. August 2009.
Power Supplies
Mains supply 100 to 240 V AC
External battery 24 V DC
Click-on battery 8 hours
Internal battery 4 hours
Dimensions
W x H x D 348 × 120 × 264 mm without click-on battery
(348 × 120 × 290 mm with click-on battery)
Weight 5.2 kg without click-on battery
(6.7 kg with click-on battery)
Noise level (at 10 cmH2O
constant pressure)
Less than 30 dB(A)
Breas Medical AB/EN/September 2009
Alarms
High Pressure, Low Pressure, High PEEP, Low PEEP, High Vt, Low
Vt, High MV, Low MV, High Breath Rate, Low Breath Rate, Apnea,
Disconnection, Rebreathing, High FiO2, Low FiO2, High Pulse Rate,
Low Pulse Rate, Last Power Source
Breas Medical